Trench Technology
Katherm HK
Article no.:
14324461112924
List price
2,090.00 CAD
zzgl. 19% MwSt.
Overview
- All factory-fitted components are wired to terminals
- Compact connecting terminal strip
- Convenient/space-saving connection area
- Power supply via on-site power supply components
- Control by Kampmann room thermostats or on-site controls
- Energy-saving, with flow-optimised impellers, cascaded arrangement as a continuous fan belt
- Easily removeable, plug & play fan
- Even air flow through convector
- Robust and whisper-quiet motor design
- Continuously variable control via external 0-10 V signal
- With anti-torsion device
- Made of the proven copper/aluminium combination, optimised for air flow and output
- Optionally available with projecting connections
- Painted graphite-grey
- Act as a finger guard for the tangential fan, filter frame, airflow baffle, grille seat and reinforcing stay to strengthen the trench
- In a 2-pipe version for additional electric heating
- With integral, continuously variably controllable electric heating coil
- With built-in safety chain consisting of 2 safety temperature switches
- Sustainable 4-pipe system solution at the cost of a 2-pipe system
- Easy removal of tangential fan without tool
- Novl coupling/cone pin system
- Simultaneous sound decoupling
- For fast and safe wiring, saves installation time
- For inducing preconditioned supply air
- Primary air volume can be adjusted
- Max. air volume per module = 60 m³/h (35 cfm)
- Amount of modules selectable depending on trench length
- Change in trench dimensions: trench width + 20 mm (0.79“); trench height + 35 mm (1.38“)
Calculate performance data
Sound power octave spectrum
The sound power is determined depending on the use according to DIN EN ISO 3741 (in the echo chamber), according to DIN EN ISO 3744 (in the low-reflective half-space) or according to DIN EN ISO 9614 (intensity method).
Oktave Spektrum
EPD data
Item number-specific LCA data based on verified EPD according to EN 15804, which is available for download at The International EPD System. Separate subdivision of life cycle modules available online via button "EPD data sheet". The environmental impacts of module B refer to 1 year of operation. A: Product and construction process stage - B: Use stage - C: End of life stage - D: Benefits and loads beyond the system boundary
Impact Category | A | B | C | D |
---|---|---|---|---|
GWP - Fossil | kg CO₂ eq | 1.17E+02 | 7.82E+00 | 4.49E+00 | -5.11E+01 |
GWP - Biogenic | kg CO₂ eq | -3.40E+00 | 9.14E-01 | 1.77E-03 | -2.48E-02 |
GWP - Luluc | kg CO₂ eq | 1.17E+00 | 3.02E-02 | 2.20E-04 | -3.71E-01 |
GWP - Total | kg CO₂ eq | 1.15E+02 | 8.76E+00 | 4.49E+00 | -5.16E+01 |
ODP | kg CFC-11 eq | 9.53E-06 | 5.28E-07 | 8.82E-08 | -3.44E-06 |
AP | mol H+ eq | 1.28E+00 | 6.34E-02 | 1.83E-03 | -7.49E-01 |
EP - Freshwater | kg P eq | 1.12E-01 | 5.38E-03 | 5.78E-05 | -6.21E-02 |
EP - Marine | kg N eq | 1.34E-01 | 7.41E-03 | 6.18E-04 | -6.39E-02 |
EP - Terrestrial | mol N eq | 1.46E+00 | 8.75E-02 | 7.10E-03 | -7.42E-01 |
POCP | kg NMVOC | 4.25E-01 | 2.19E-02 | 1.56E-03 | -2.15E-01 |
ADPE | kg Sb eq | 1.78E-02 | 1.80E-03 | 1.39E-06 | -1.42E-02 |
ADPF | MJ | 1.58E+03 | 1.93E+02 | 4.57E+00 | -6.30E+02 |
WDP | m³ depriv. | 3.04E+01 | 1.25E+00 | 1.40E-01 | -1.11E+01 |
PM | disease inc. | 8.58E-06 | 2.28E-07 | 2.78E-08 | -3.89E-06 |
IR | kBq U-235 eq | 1.77E+01 | 6.39E+00 | 2.66E-02 | -5.45E+00 |
ETP - FW | CTUe | 8.19E+03 | 4.26E+02 | 1.87E+01 | -5.48E+03 |
HTP - C | CTUh | 5.73E-07 | 1.49E-08 | 5.92E-10 | -2.91E-07 |
HTP - NC | CTUh | 1.30E-05 | 6.17E-07 | 9.51E-09 | -8.55E-06 |
SQP | Pt | 9.10E+02 | 8.56E+01 | 6.50E+00 | -3.00E+02 |
PERE | MJ | 4.34E+02 | 3.59E+01 | 1.49E-01 | -1.21E+02 |
PERM | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
PERT | MJ | 4.34E+02 | 3.59E+01 | 1.49E-01 | -1.21E+02 |
PENRE | MJ | 1.58E+03 | 1.93E+02 | 4.57E+00 | -6.30E+02 |
PENRM | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
PENRT | MJ | 1.58E+03 | 1.93E+02 | 4.57E+00 | -6.30E+02 |
SM | kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
RSF | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
NRSF | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
FW | m³ | 7.48E-01 | 7.81E-02 | 5.75E-03 | -3.50E-01 |
HWD | kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
NHWD | kg | 6.27E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
RWD | kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
CRU | kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
MFR | kg | 0.00E+00 | 0.00E+00 | 1.90E+01 | 0.00E+00 |
MER | kg | 0.00E+00 | 0.00E+00 | 1.50E+00 | 0.00E+00 |
EE (Electrical) | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
EE (Thermal) | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
*GWP-GHG | kg CO₂ eq | 1.15E+02 | 7.76E+00 | 4.49E+00 | -4.97E+01 |
Accessories
Control accessories electromechanical 24 V
Clock thermostat
Heating/Cooling, 2- and 4-pipe, continuously variable, with LCD operating menu and integrated timer program, heating/cooling changeover by means of external potential-free contact (low voltage), 24 V Actuator, Open/Closed, 1 W, flush-mounted, Protection class IP 30, Colour similar to RAL 9010 pure white, Type 30456
Only in conjunction with valves/valve kits!
optional connectible, remote sensor art. no. 196000148921
can optionally be connected, clip-on sensor art. no. 196000148922
Suitable for: EC units, electromechanical 24 V/230 V, 5 Katherm HK, Katherm HK 320 E, Katherm QK or Katherm QK nano Trench Technology, 5 PowerKon nano Perimeter Heating
Only in conjunction with valves/valve kits!
optional connectible, remote sensor art. no. 196000148921
can optionally be connected, clip-on sensor art. no. 196000148922
Suitable for: EC units, electromechanical 24 V/230 V, 5 Katherm HK, Katherm HK 320 E, Katherm QK or Katherm QK nano Trench Technology, 5 PowerKon nano Perimeter Heating
Article no.:
196000030456
List price
410.00 CAD
zzgl. 19% MwSt.
Power supply unit
for external installation outside the trench heater, 85 - 264 V AC, 24 V DC, 36 W, on DIN rail, Protection class II
Suitable for: EC units, electromechanical 24 V, 1 Katherm QK Trench Technology, 3 Katherm QK nano Trench Technology, 3 PowerKon nano Perimeter Heating
Suitable for: EC units, electromechanical 24 V, 1 Katherm QK Trench Technology, 3 Katherm QK nano Trench Technology, 3 PowerKon nano Perimeter Heating
Article no.:
196901335152
List price
56.00 CAD
zzgl. 19% MwSt.
Power supply unit
for external installation outside the trench heater, 86 - 264 V AC, 24 V DC, 47 Hz, 60 W, on DIN rail, Protection class II
Suitable for: EC units, electromechanical 24 V, 2 Katherm QK Trench Technology, 5 Katherm QK nano Trench Technology, 6 PowerKon nano Perimeter Heating
Suitable for: EC units, electromechanical 24 V, 2 Katherm QK Trench Technology, 5 Katherm QK nano Trench Technology, 6 PowerKon nano Perimeter Heating
Article no.:
196901338401
List price
74.00 CAD
zzgl. 19% MwSt.
Valve kits
Valve kit
Heating/Cooling, 4-pipe, includes 2 pre-settable valves, 2 actuators, 1 straight and 1 angled return shut-off valve, 24 V actuator, with two axial valves, pre-settable, one angled return shut-off valve, one straight return shut-off valve, and two thermoelectric actuators 24 V, Connection 1/2'', kvs value 1 m³/h, Max. operating pressure 10 bar, supplied separately
Suitable for: DN 15
Suitable for: DN 15
Article no.:
194000143411
List price
291.00 CAD
zzgl. 19% MwSt.
Valve kit
Heating/Cooling, 4-pipe, 2 pre-settable valves, 2 actuators, 1 straight and angled return shut-off valve respectively, with two axial valves, pre-settable, one angled return shut-off valve, one straight return shut-off valve, and two thermoelectric actuators 24 V, 24 V actuator, Connection 1/2'', kvs value 2.65 m³/h, Max. operating pressure 16 bar, supplied separately
Suitable for: for higher flow from 250 l/h, DN 15
Suitable for: for higher flow from 250 l/h, DN 15
Article no.:
194000143441
List price
303.00 CAD
zzgl. 19% MwSt.
Valves and return shut-off valves
Valve body
Axial, pre-settable, Connection 1/2'', kvs value 1 m³/h, Max. operating pressure 10 bar
Suitable for: Katherm NK 137/182 (trench heights 92 mm and 120 mm), DN 15
Suitable for: Katherm NK 137/182 (trench heights 92 mm and 120 mm), DN 15
Article no.:
194000346911
List price
39.00 CAD
zzgl. 19% MwSt.
Valve body
Axial, pre-settable, Connection 1/2'', kvs value 2.65 m³/h, Max. operating pressure 16 bar
Suitable for: for higher flow from 250 l/h, DN 15
Suitable for: for higher flow from 250 l/h, DN 15
Article no.:
194000346914
List price
51.00 CAD
zzgl. 19% MwSt.
Pre-setting key
Once per project necessary.
Suitable for: pre-settable valve bodies, valve kits and convector connection kit
Suitable for: pre-settable valve bodies, valve kits and convector connection kit
Article no.:
194000346915
List price
7.00 CAD
zzgl. 19% MwSt.
Pre-setting set
Suitable for: pre-settable valve bodies and valve kits with higher flow from 250 l/h
Article no.:
194000346916
List price
38.00 CAD
zzgl. 19% MwSt.
Return shut-off valve
Straight, Connection 1/2''
Article no.:
194000145952
List price
21.00 CAD
zzgl. 19% MwSt.
Return shut-off valve
angled, Connection 1/2''
Article no.:
194000145953
List price
21.00 CAD
zzgl. 19% MwSt.
Return shut-off valve
Straight, Connection 1/2''
Suitable for: for higher flow from 250 l/h
Suitable for: for higher flow from 250 l/h
Article no.:
194000145954
List price
34.00 CAD
zzgl. 19% MwSt.
Return shut-off valve
angled, Connection 1/2''
Suitable for: for higher flow from 250 l/h
Suitable for: for higher flow from 250 l/h
Article no.:
194000145955
List price
31.00 CAD
zzgl. 19% MwSt.
Valve actuators
Thermoelectric actuator
24 V AC/DC
Suitable for: Katherm, control configuration KaControl -C1 and clock thermostat type 30456
Suitable for: Katherm, control configuration KaControl -C1 and clock thermostat type 30456
Article no.:
194000146906
List price
84.00 CAD
zzgl. 19% MwSt.
Filter
Filter for air inlet
Replacement filter without frame, ISO Coarse 30% filter (G2)
Suitable for: Length 1700 mm
Suitable for: Length 1700 mm
Article no.:
143014313029
List price
31.00 CAD
zzgl. 19% MwSt.
Installation covers
Installation cover
to protect trench during installation, factory-fitted, grilles are packed separately
price per m
Suitable for: Width 245 mm
price per m
Suitable for: Width 245 mm
Article no.:
194000100245
List price
21.00 CAD
zzgl. 19% MwSt.
Downloads
Cross-product information
Products
PDF
(7.5 MB)
Overview Katherm supply air versions
PDF
(4.1 MB)
Overview Trench Systems
PDF
(3.3 MB)
Declarations/Certificates
Certificate ISO 50001:2018
PDF
(194 kB)
Certificate ISO 9001:2008
PDF
(118 kB)
Digital EPD database Katherm HK E
Digital EPD database Katherm HK
EPD Katherm HK E
PDF
(1.6 MB)
ETL Authorisation to mark Katherm and Baseboard HK and QK
PDF
(100 kB)
EPD Katherm HK
PDF
(2.5 MB)
BIM data (Building Information Modeling)
Kampmann Group BIM data
Technical catalogues
Katherm HK trench heating
PDF
(17.3 MB)
Manuals
Katherm HK trench heating
PDF
(5.5 MB)
Katherm HK, brief instructions
PDF
(3.8 MB)
CAD-Drawings
Katherm HK, Kanalbreite 245 mm, Kanalhöhe 160 mm, 4-Leiter, Abmessungen [Inch]
PDF
(378 kB)
Katherm HK, Kanalbreite 245 mm, Kanalhöhe 160 mm, 4-Leiter, Abmessungen [mm]
PDF
(529 kB)
Katherm HK, Kanalbreite 245 mm, Kanalhöhe 160 mm, 4-Leiter, Abmessungen [Inch]
DWG
(1.2 MB)
Katherm HK, Kanalbreite 245 mm, Kanalhöhe 160 mm, 4-Leiter, Abmessungen [mm]
DWG
(1.2 MB)