Trench Technology
Katherm QK nano
Article no.:
44217072233724
List price
1,942.00 CAD
zzgl. 19% MwSt.
Overview
- All factory-fitted components are wired to terminals
- Compact connecting terminal strip
- Convenient/space-saving connection area
- Power supply via on-site power supply components
- Control by Kampmann room thermostats or on-site controls
The Eurokonus valve connection enables the Katherm QK nano to be quickly and easily installed on site. In addition, height adjustment feet and raised floor height adjustment feet are supplied as standard to further reduce the installation time and thus the cost.
- For valves and electrical components
- With cover for visual protection and to protect against dirt
- Prevents damage to the convector when installing the valves or threaded connectors
- For the simple fixing of the floor trench
- With rubber underlay for acoustic decoupling
- Power supply 24V
- Available in 30, 60 and 100 W versions
- Optional DIN rail Class 2 Transformers for 120V/60Hz supply
- Fan speed control 20 to 100 % via 0-10V BMS signal
24 V electromechanical
Calculate performance data
Sound power octave spectrum
The sound power is determined depending on the use according to DIN EN ISO 3741 (in the echo chamber), according to DIN EN ISO 3744 (in the low-reflective half-space) or according to DIN EN ISO 9614 (intensity method).
Oktave Spektrum
EPD data
Item number-specific LCA data based on verified EPD according to EN 15804, which is available for download at The International EPD System. Separate subdivision of life cycle modules available online via button "EPD data sheet". The environmental impacts of module B refer to 1 year of operation. A: Product and construction process stage - B: Use stage - C: End of life stage - D: Benefits and loads beyond the system boundary
Impact Category | A | B | C | D |
---|---|---|---|---|
GWP - Fossil | kg CO₂ eq | 5.61E+01 | 5.15E+00 | 3.44E+00 | -2.89E+01 |
GWP - Biogenic | kg CO₂ eq | 9.69E-02 | 7.37E-03 | 4.34E-04 | -4.79E-02 |
GWP - Luluc | kg CO₂ eq | 2.26E-01 | 3.00E-02 | 2.72E-04 | -1.59E-01 |
GWP - Total | kg CO₂ eq | 5.65E+01 | 5.18E+00 | 3.44E+00 | -2.92E+01 |
ODP | kg CFC-11 eq | 1.89E-06 | 2.27E-07 | 6.24E-08 | -7.38E-07 |
AP | mol H+ eq | 7.05E-01 | 5.47E-02 | 1.55E-03 | -4.52E-01 |
EP - Freshwater | kg P eq | 5.98E-02 | 4.01E-03 | 7.04E-05 | -3.77E-02 |
EP - Marine | kg N eq | 1.36E-01 | 1.23E-02 | 5.27E-04 | -3.78E-02 |
EP - Terrestrial | mol N eq | 8.19E-01 | 6.79E-02 | 5.39E-03 | -4.50E-01 |
POCP | kg NMVOC | 3.07E-01 | 1.99E-02 | 1.74E-03 | -1.79E-01 |
ADPE | kg Sb eq | 6.43E-03 | 5.68E-04 | 1.29E-06 | -4.64E-03 |
ADPF | MJ | 7.34E+02 | 1.18E+02 | 3.65E+00 | -3.54E+02 |
WDP | m³ depriv. | 1.54E+01 | 8.68E-01 | 1.48E-01 | -6.54E+00 |
PM | disease inc. | 4.58E-06 | 2.07E-07 | 2.30E-08 | -2.36E-06 |
IR | kBq U-235 eq | 5.73E+00 | 3.77E+00 | 1.69E-02 | -2.37E+00 |
ETP - FW | CTUe | 1.09E+03 | 9.57E+01 | 2.65E+01 | -5.03E+02 |
HTP - C | CTUh | 2.85E-07 | 1.05E-08 | 5.65E-10 | -1.60E-07 |
HTP - NC | CTUh | 7.02E-06 | 5.82E-07 | 6.37E-09 | -4.91E-06 |
SQP | Pt | 4.91E+02 | 6.51E+01 | 3.70E+00 | -1.51E+02 |
PERE | MJ | 1.29E+02 | 2.67E+01 | 2.10E-01 | -5.69E+01 |
PERM | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
PERT | MJ | 1.29E+02 | 2.67E+01 | 2.10E-01 | -5.69E+01 |
PENRE | MJ | 7.34E+02 | 1.18E+02 | 3.65E+00 | -3.54E+02 |
PENRM | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
PENRT | MJ | 7.34E+02 | 1.18E+02 | 3.65E+00 | -3.54E+02 |
SM | kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
RSF | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
NRSF | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
FW | m³ | 5.65E-01 | 6.35E-02 | 3.80E-03 | -2.25E-01 |
HWD | kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
NHWD | kg | 3.59E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
RWD | kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
CRU | kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
MFR | kg | 0.00E+00 | 0.00E+00 | 1.10E+01 | 0.00E+00 |
MER | kg | 0.00E+00 | 0.00E+00 | 1.32E+00 | 0.00E+00 |
EE (Electrical) | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
EE (Thermal) | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
*GWP-GHG | kg CO₂ eq | 5.65E+01 | 5.20E+00 | 3.44E+00 | -2.92E+01 |
Accessories
Control accessories electromechanical 24 V
Clock thermostat
Heating/Cooling, 2- and 4-pipe, continuously variable, with LCD operating menu and integrated timer program, heating/cooling changeover by means of external potential-free contact (low voltage), 24 V Actuator, Open/Closed, 1 W, flush-mounted, Protection class IP 30, Colour similar to RAL 9010 pure white, Type 30456
Only in conjunction with valves/valve kits!
optional connectible, remote sensor art. no. 196000148921
can optionally be connected, clip-on sensor art. no. 196000148922
Suitable for: EC units, electromechanical 24 V/230 V, 5 Katherm HK, Katherm HK 320 E, Katherm QK or Katherm QK nano Trench Technology, 5 PowerKon nano Perimeter Heating
Only in conjunction with valves/valve kits!
optional connectible, remote sensor art. no. 196000148921
can optionally be connected, clip-on sensor art. no. 196000148922
Suitable for: EC units, electromechanical 24 V/230 V, 5 Katherm HK, Katherm HK 320 E, Katherm QK or Katherm QK nano Trench Technology, 5 PowerKon nano Perimeter Heating
Article no.:
196000030456
List price
410.00 CAD
zzgl. 19% MwSt.
Power supply unit
for external installation outside the trench heater, 85 - 264 V AC, 24 V DC, 36 W, on DIN rail, Protection class II
Suitable for: EC units, electromechanical 24 V, 1 Katherm QK Trench Technology, 3 Katherm QK nano Trench Technology, 3 PowerKon nano Perimeter Heating
Suitable for: EC units, electromechanical 24 V, 1 Katherm QK Trench Technology, 3 Katherm QK nano Trench Technology, 3 PowerKon nano Perimeter Heating
Article no.:
196901335152
List price
56.00 CAD
zzgl. 19% MwSt.
Power supply unit
for external installation outside the trench heater, 86 - 264 V AC, 24 V DC, 47 Hz, 60 W, on DIN rail, Protection class II
Suitable for: EC units, electromechanical 24 V, 2 Katherm QK Trench Technology, 5 Katherm QK nano Trench Technology, 6 PowerKon nano Perimeter Heating
Suitable for: EC units, electromechanical 24 V, 2 Katherm QK Trench Technology, 5 Katherm QK nano Trench Technology, 6 PowerKon nano Perimeter Heating
Article no.:
196901338401
List price
74.00 CAD
zzgl. 19% MwSt.
Power supply unit
for external installation outside the trench heater, 86 - 264 V AC, 24 V DC, 47 Hz, 92 W, on DIN rail, Protection class II
Suitable for: EC units, electromechanical 24 V, 4 Katherm QK Trench Technology, 7 Katherm QK nano Trench Technology, 10 PowerKon nano Perimeter Heating
Suitable for: EC units, electromechanical 24 V, 4 Katherm QK Trench Technology, 7 Katherm QK nano Trench Technology, 10 PowerKon nano Perimeter Heating
Article no.:
196901338402
List price
106.00 CAD
zzgl. 19% MwSt.
Valve kits
Valve kit
with pre-settable valve body, return shut-off valve and matching spacer, 24 V actuator, kvs value 1 m³/h, Max. operating pressure 10 bar
Suitable for: DN 15
Suitable for: DN 15
Article no.:
194000442100
List price
156.00 CAD
zzgl. 19% MwSt.
Connection accessories
Connection set
with two return shut-off valves and matching adapter; when using the Katherm QK nano with a central manifold
Article no.:
194000442101
List price
75.00 CAD
zzgl. 19% MwSt.
Installation covers
Installation cover
to protect trench during installation, factory-fitted, grilles are packed separately
price per m
Suitable for: Width 165 mm
price per m
Suitable for: Width 165 mm
Article no.:
194000101916
List price
15.00 CAD
zzgl. 19% MwSt.
Downloads
Cross-product information
Products
PDF
(7.5 MB)
Overview Katherm supply air versions
PDF
(4.1 MB)
Overview Trench Systems
PDF
(3.3 MB)
Declarations/Certificates
Certificate ISO 50001:2018
PDF
(194 kB)
Certificate ISO 9001:2008
PDF
(118 kB)
Digital EPD database Katherm QK nano
EPD Katherm QK nano
PDF
(9.3 MB)
ETL Authorisation to mark Katherm and Baseboard HK and QK
PDF
(100 kB)
BIM data (Building Information Modeling)
Kampmann Group BIM data
Manuals
Katherm QK nano trench heating
PDF
(1.6 MB)
Installation plans
Katherm QK nano, 24 V electromechanical model
PDF
(685 kB)
CAD-Drawings
Katherm QK nano, trench length 2100 mm, 24 V control, cross-sections, views
PDF
(121 kB)
Katherm QK nano, trench length 2100 mm, 24 V control, cross-sections, views
DWG
(413 kB)
Katherm QK nano, trench length 2100 mm, 24 V control, cross-sections, views
DXF
(1.6 MB)